The largest member of our diesel family of generators is the EDL11000SDE. Despite its high output, its compact design, low overall height and reduced noise levels make it a versatile performer. If lower running costs and easier maintenance access are important to your business, farm, job site or off grid application, then check out extensive range of features the EDL11000SDE offers.
- There are no features available
Engine | |
---|
Model | D722 diesel; 719cc, liquid-cooled (with rad & cooling fan), three cylinder, 2-valve, 4-stroke diesel |
Rated Output Engine / Engine RPM | 12.2 kW (16.4 hp) / 3,600 rpm |
Starting System | Electric starting |
Ignition | Electronic ignition |
Recommended Fuel | Ultra low sulfur, Diesel fuel No.2-D (above -10C) / Diesel fuel No.1-D (below -10C) |
Engine Oil Capacity | 3.4 L |
General | |
---|
L x W x H mm (in) | 1281 x 618 x 698 mm (50.4 x 24.3 x 27.5") |
Dry Weight | 295 kg (650 lbs.) |
Fuel Tank Capacity (L) | 28 |
Operating Hours (@ rated load) | 7 hrs |
Noise Level (@ 7 metres) | 69 dB |
Generator | |
---|
Type | Brush-type, Syncronous, AC generator |
Maximum AC Output (watts / amperes) | 11 kW (11,000 W) |
Rated AC Output (watts / amperes) - Continuous Use | 10 kV / 10,000 W / 83.3 A @ 120 V & 41.7A @ 240 V |
AC Voltage & Frequency (HZ) | 120 & / 240 V / 60 HZ |
Neutral | Bonded to frame |
AC Receptacle* | L5 30 (30A - 125V) / L6 30 (30A - 250V) / 14R 50 (50A - 125/250V) / 5 - 20R GFCI x 2 |
Technical Features | |
---|
Non-Fuse Circuit Breaker System (NFB) | Standard |
Sub Circuit Breaker For Each Receptacle | Standard |
Dual 120 & 240 Voltage | Standard |
Pilot Lamp (AC output) | Standard |
Oil Watch Warning System | Standard |
Oil Pressure Warning System (Engine Shut Down) | Standard |
Coolant Temperature Warning System (Engine Shutdown) | Standard |
GFCI Protected Receptacles | Standard |
Hour Meter | Standard |
Fuel Level Gauge | Standard |
Volt Meter | Standard |
Warranty | |
---|
Private Use† | 3-years limited |
Commercial Use† | 3-years limited |